Skip to main content

Overview of terminal blocks

Overview of terminal blocks

Illustration 14: Overview of terminal blocks

Safety blocks S1 through S6 are highlighted in blue.

Secure inputs/outputs

The safe inputs and outputs can be used to monitor safety devices and control actuators.

Overview of safety terminal blocks, grouped by function

S1¹²S2¹²S3¹²
24 V1024 V10Surveillance robot stopped10E
Ground9Ground9Pulse 1 (output)9
Emergency stop channel 1 (input)8A24 V8Ground8
Emergency stop 1 (output)7Ground7Robot stopped 1.1 (output)7
Emergency stop channel 2 (input)6Ground6CRobot stopped 1.2 (output)6
Emergency stop 2 (output)5Robot not stopped 1.15System stop monitoring 25F
24 V4BRobot not stopped 1.24Pulse 1 (output)4
External reset ON3Ground3DGround3
Ground2System stop 1.1 (output)2System stop 2.1 (output)2
Reset LED (output)1System stop 1.2 (output)1System stop 2.2 (output)1

¹ Sequence number

² Group

S4¹²S5¹²S6¹²
Auto mode (input)10GGround10JGround10L
Manual mode (input)9Safe input 1.19Safe input 3.19
Pulse 1824 V824 V8
System/emergency stop relay output 17HSafe input 1.27Safe input 3.27
System/emergency stop relay input 1624 V624 V6
System/emergency stop relay output 25Ground5KGround5M
System/emergency stop relay input 24Safe input 2.14Safe input 4.14
Ground3I24 V324 V3
Safe home/wait position 1 (output)2Safe input 2.22Safe input 4.22
Safe home position 2 (output)124 V124 V1

¹ Sequence number

² Group

The following table describes the function of each safe input/output:

DesignationDescriptionPart of the group
24 V+24 VDC output
GND (ground)0 VDC
Safe input x.xSafety inputsJ, K, L, M
Pulse xPersistent OSSD output
Emergency stop x InIncoming connection from an emergency stop deviceA
Emergency stop x OutOutgoing connection to an emergency stop deviceA
Ext. reset input24 V input: Confirmation of the safe operational readiness of the systemB
Reset LED output24-V output for connecting a white reset LEDB
Robot not stopped x24 V output
24 V (HIGH) when a system stop is requested and the robot is safely at a standstill. (Reversal of the "Robot Stopped" output)
C
System stop x24 V output
0 (LOW) when a safe stop 0, 1, or 2 is requested
D, F
System stop monitoringReserved for future function expansionF
Robot stopped24 V output
0 (LOW) when a system stop is requested and the robot is safely at a standstill
E
Surveillance robot stoppedReserved for future function expansionE
Automatic modePulse 1 input for activating automatic mode (to be used only upon special request)G
Manual modePulse 1 input for activating manual mode (to be used only upon special request)G
Stop relay output xConfigurable relay output from relay X. Emergency stop or system stop (default: emergency stop)H
Stop relay input xInput current for the relay output of relay XH
Safe starting position x24 V (HIGH) when the base module and each drive module of the robot are in their respective starting positions (default value: 0 degrees).I

For further details and information on cabling, see Electrical installation.